Home » Solar » Why NSW large-scale solar farms are delivering a bigger bang for their buck

Why NSW large-scale solar farms are delivering a bigger bang for their buck

Parkes solar farm
Parkes solar farm rated the best in terms of revenue per MW installed.

Last week I presented at the Clean Energy Council’s Large-Scale Solar Forum on the topic “Exploring the market performance of large-scale solar farms across the NEM in 2020”, based on data from the Generator Statistical Digest 2020, a recent publication by Global-Roam and Greenview Strategic Consulting. Here’s a look at one of the measures of performance.

I’ve chosen the metric Revenue per Megawatt (MW) of Maximum Capacity to compare the performance of large-scale solar farms. I chose this metric in preference to two other metrics often used in league tables:

  • Capacity factor (MWh generation divided by MWh at continuous maximum output): This is interesting as a comparison of technical performance, but doesn’t capture whether the energy was valuable when generated;
  • Volume-Weighted Average Price (weighted average of market price by generation MWh each trading interval): This is a big improvement on capacity factor for capturing the value of the energy, but with the increasing incidence of negative prices and of solar farms incentivised to reduce output in response, the VWAP can be misleading. Imagine a solar farm that chose to run only for one hour a year when the prices were high. It’d have a spectacular VWAP – but negligible annual revenue.

The metric Revenue per MW of Maximum Capacity attempts to compare estimated spot-market revenue return across farms of different sizes by normalising using MW of Maximum Capacity as a rough proxy to the capital cost.

Note: There are two figures that AEMO publishes from generator registration information – the “Registered Capacity”, which is the “nameplate rating” of the site – for a solar farm, typically the PV panels installed, while the “Maximum Capacity” is the maximum the farm can dispatch – which is limited by its network connection. Many recent solar farms have Registered Capacity exceeding Maximum Capacity to get a better return on the expensive network connection capacity.

The comparison here is made using only public data from AEMO’s market systems, so doesn’t take account of a lot of factors (including hedging arrangements, operational costs and green certificate value) that would be needed to calculate the return to the owners.

What it does indicate is the spot market revenue creation ability of the farm, which might not be of much interest to a PPA-holding developer, but is of a lot of interest to the offtaker (the counterparty to the PPA), to market-exposed generators, and to investors in future solar farms.

Some notes on the detail:

  • Only solar farms that were operational for all of 2020 are included.
  • Spot Revenue is estimated from AEMO public data (using DISPATCH_UNIT_SCADA to estimate generation), accounting for applicable loss factors.
  • Maximum Capacity was chosen for normalisation, but it could be argued that Registered Capacity is a better measure, or somewhere in between. The dotted line on the graph shows the metric Revenue / Registered Capacity. Using this metric changes the ordering a little but not a lot.

A few observations:

  • The NSW sites on the whole are performing a lot better than the Queensland sites on the metric Spot Revenue / MW Maximum Capacity. The best performing NSW farm (Parkes) is estimated to have annual spot revenue of $160,000/MW, compared to the best QLD site (Longreach) at $80,000/MW.
  • In VIC, Numurkah did well, but the other VIC sites are significantly lower in relative revenue, mostly due to the impact of constraints from an oscillation problem early in 2020.
  • Four of the top five performing sites were in operation before 2018.
  • In SA, we see Tailem Bend and Bungala One scoring similarly on this metric, which is quite different to their results on the other two metrics I mentioned above, given their very different bidding strategies. Tailem Bend’s VWAP for 2020 was about $42/MWh with capacity factor 19%, compared to Bungala 1’s VWAP of about $32/MWh with capacity factor 27%.

In a future article I’ll have a look at how the results change when an estimate of the value of the LGCs created is added in.

Source: Watt Clarity. Reproduced with permission.

Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
Get up to 3 quotes from pre-vetted solar (and battery) installers.
0
Would love your thoughts, please comment.x
()
x