Figure 3 QLD supply and pool price. Source: NEM Review
“O ye’ll tak’ the high road, and I’ll tak’ the low road,
And I’ll be in Scotland a’fore ye,
But me and my true love will never meet again,
On the bonnie, bonnie banks o’ Loch Lomond”
Loch Lomond 1841
Why you should read this note:
Despite the high gas prices, but because of high electricity price forecasts, in turn partly due to high gas prices, we think that significant new gas generation may be built in the NEM.
AGL has already announced the reciprocating engine 230 MW Barkers Inlet plant in South Australia. It’s true that this is notionally a replacement for TIPS A but the reality is its new generation that will run a lot harder.
AGL in its last results and as part of its NSW Liddell replacement strategy has announced its looking into a new 250 MW plant at Newcastle.
EnergyAustralia has also announced potentially reaching a finance investment decision later this year on as much as 1000MW of new gas generation at Tallawarra and Marulan in NSW
Snowy Hydro executives have mulled the possibility of a new gas plant being built in NSW prior to completion of Snowy 2.0 pumped hydro scheme.
AGL will lose market share in NSW generation, as it has lost it in gas retailing, if it builds just 250 MW and EA builds 1000 MW but that’s another story.
Neither AGL, nor EA, nor Snowy, nor Origin want to own renewable generation. All prefer to buy it from others, or in AGL’s case to take a minority equity investment in a renewable funding vehicle.
But by trying to play both ends of the candle, that is keeping prices high to customers but buying cheap from renewable developers, they run the risk of being cut out via the corporate PPA.
In particular they allow room for a renewables focused generator, eg Goldwind or Neon or RES, to back fill its renewable portfolio with firming capacity and start going direct to customers.
Long live the market, but again it’s another story. We should stick to gas today.
Outside of the coal “Boom and Bust” report from Coalswarm, Greenpeace and the Sierra Club the most interesting piece of research we’ve read recently comes from NREL’s Paul Denholm, who apparently did some of the early investigation of the increasingly infamous California duck curve.
That curve development is four years ahead of its original schedule seen in 2010.
It shows that California ramps up 15 GW of power.
So far California, having seen the duck curve coming, has dealt with it via flexible “shoulder” (or should it be “neck”) plant and by trying to shift demand. In best American naming practice this is the “fatten & flatten” strategy.
Clearly though there is still a very steep ramp required. Everyone recognizes that the challenge of going from 50% renewables to 100% renewables seems to be tougher than getting to 50% renewables.
In California the challenge is arriving rapidly not just because the penetration of PV has been more rapid than originally forecast but also because a significant portion of the gas generation is likely to retire.
Gas generation will retire both because of age but also because of Californiaa’s “once through cooling” rule which will prohibit using sea or river water from cooling and then returning the heated water to the river or ocean.
The once through cooling rule will require about 11 GW to be shuttered by 2029
According to Denholm’s recent NREL publication California [CA] has around 21 GW of peaking generation capacity. About 12 GW of this capacity is at least 40 years old and in the USA the average of shutdown gas plants is 44 years.
The chart shows that very little plant was installed between 1980 and 2000 and for a grid of CA’s size not all that much even since 2000. The plant likely to be closed has capacity factors that average around 15%.
One feature of the duck curve easy to overlook is the bump in the curve in the evening when peak demand falls off. That can be seen in Fig 1 up around 6 pm. However we can also see the same thing in Queensland over the past 12 months.
We start by looking at the daily average supply and pool price for the past 12 months.
This is the period when QLD has acted to keep prices down. You can see the price spike around the 6-7:30 PM
If we then look at a closeup of the above graph and measure Qld thermal demand + rooftop PV what we see is there is a peak in thermal demand around 7 PM that is 60 MW higher than 6:30 PM.
So a relatively small battery 60 MW/30 minutes could knock off that peak. 30 minutes is already in the area where batteries have economic advantage over say either gas or pumped hydro.
As it happens that half hour is about the half hour where daily peak average price has been at around $110 MWh.
However, the task for batteries gets more challenging as you try to flatten the thermal supply curve further. To knock of the 5PM to 8PM peak takes about 300 MW of power with 3 hours of storage or about 30X more expensive than just the peak half hour.
And then of course at the other end the recharge requirement will be longer and likely more expensive per MWh. Actually the chart below shows that there could be a case in QLD at the moment for 60 minutes of battery covering the 6PM to 7:00 PM slot and would take 110 MWh of battery.
That’s still in the battery sweet spot of price compared to the cost of pumped hydro or open cycle gas.
No doubt even more pointed examples could be found in South Australia.
At present you need about 26 -29 MW of battery for about an hour to flatten the peak. Again this is well with the time duration where batteries are economically advantaged compared to other forms of generation.
Equally demand management might be cheaper again. But actually we doubt it.
We think that batteries are most usefully located on the “fringe of the grid” that is behind the meter located right next to the point of consumption.
However, in this section we review a second Denholm paper that looks at the advantages and disadvantages of AC v DC coupling and on site v remote location for PV + Storage in the USA.
Most utility-scale PV plants and virtually all single axis tracking plants have a panel capacity that exceeds the inverter capacity. A typical ratio is say 70 MW DC to 50 MW AC or about 1.3- 1.4.
In general these ratios have increased in recent years. The main reason historically has been that panels only rarely produce at their rated capacity.
However, in recent years a second reason has been attempts to produce output both earlier and later than fixed tilt systems. It costs more to put extra panels in but total output increases and some of the output is more valuable.
In NSW the figure below shows that over the past 12 months Moree single axis tracking plant had about a 38% higher capacity factor (output expressed as index) and would have earned 40% more spot revenue.
However, even Moree couldn’t capture either the early morning or evening peak spot price properly
Let’s assume that you want to add storage to a system such as Moree. A DC coupled system cannot access many ancillary revenue streams.
The following table shows some very, very, rough estimates of required revenues to earn an annual 6% return. Other ways of looking at this are LCOE or benefit to cost ratios.
Benefit to cost ratios have the advantage of taking available revenues into account as well as costs. Still we just look at an accounting measure because the assumptions are so crude.
We assume the marginal MW of PV only faces the EPC construction cost of say A$1.10 -$1.20 watt. We assume that the battery, without inverter but with an MPPT can be installed for as little as A$0.8 m MWh.
Most crucially in some ways we assume that his marginal MW of DC capacity is clipped 40% of the time (so its free energy to charge the battery) but can sell its output into the spot PV market 60% of the time.
Under these assumptions the battery is almost economic in the current NSW spot market assuming a 6% annual return is required and that there are no incremental opex costs.
The unclipped revenue gets the weighted average spot price of $89 MWh which means the battery has to get $109 MWh. Adding more storage would hurt the economics.
David Leitch is principal of ITK. He was formerly a Utility Analyst for leading investment banks over the past 30 years. The views expressed are his own. Please note our new section, Energy Markets, which will include analysis from Leitch on the energy markets and broader energy issues. And also note our live generation widget, and the APVI solar contribution.
WA Labor signs MOU with Tesla to build a battery "remanufacturing facility" next to Neoen's…
Danish energy giant begins construction of the first giga-scale battery project in Australia's most advanced…
Hearing to help decide fate of solar farm that attracted more than 50 objections is…
Woodside boss repeats claim that Australian gas exports are helping to displace coal in Asia.…
In pulling support for the CQ-H2 green ammonia export project, Queensland’s LNP has chosen tantrum…
Rio Tinto is looking to add battery storage to contracted wind and solar to power…